racadm>>getsel
racadm getsel
Record: 1
Date/Time: 10/18/2018 23:30:19
Source: system
Severity: Ok
Description: Log cleared.
-------------------------------------------------------------------------------
Record: 2
Date/Time: 06/20/2020 03:19:23
Source: system
Severity: Critical
Description: Fault detected on drive 2 in disk drive bay 1.
-------------------------------------------------------------------------------
Record: 3
Date/Time: 06/20/2020 03:19:48
Source: system
Severity: Ok
Description: Drive 2 in disk drive bay 1 is operating normally.
-------------------------------------------------------------------------------
racadm>>racadm lclog view
...
SeqNumber = 173
Message ID = PDR1017
Category = System
AgentID = SEL
Severity = Information
Timestamp = 2020-06-20 03:19:48
Message = Drive 2 in disk drive bay 1 is operating normally.
Message Arg 1 = 2
Message Arg 2 = 1
RawEventData = 0x03,0x00,0x02,0x54,0x80,0xED,0x5E,0x20,0x00,0x04,0x0D,0x9A,0xEF,0xA1,0x01,0x02
FQDD = Disk.Bay.1-2
--------------------------------------------------------------------------------
SeqNumber = 172
Message ID = PDR5
Category = Storage
AgentID = iDRAC
Severity = Warning
Timestamp = 2020-06-20 03:19:46
Message = Disk 2 in Backplane 1 of Integrated RAID Controller 1 is removed.
Message Arg 1 = Disk 2 in Backplane 1 of Integrated RAID Controller 1
FQDD = Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
--------------------------------------------------------------------------------
SeqNumber = 171
Message ID = LOG007
Category = Audit
AgentID = DE
Severity = Information
Timestamp = 2020-06-20 03:19:46
Message = The previous log entry was repeated 1 times.
Message Arg 1 = 1
--------------------------------------------------------------------------------
SeqNumber = 170
Message ID = PDR87
Category = Storage
AgentID = iDRAC
Severity = Information
Timestamp = 2020-06-20 03:19:36
Message = Disk 2 in Backplane 1 of Integrated RAID Controller 1 was reset.
Message Arg 1 = Disk 2 in Backplane 1 of Integrated RAID Controller 1
FQDD = Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
--------------------------------------------------------------------------------
SeqNumber = 169
Message ID = PDR1001
Category = System
AgentID = SEL
Severity = Critical
Timestamp = 2020-06-20 03:19:23
Message = Fault detected on drive 2 in disk drive bay 1.
Message Arg 1 = 2
Message Arg 2 = 1
RawEventData = 0x02,0x00,0x02,0x3B,0x80,0xED,0x5E,0x20,0x00,0x04,0x0D,0x9A,0x6F,0xA1,0x01,0x02
FQDD = Disk.Bay.1-2
--------------------------------------------------------------------------------
SeqNumber = 168
Message ID = PDR60
Category = Storage
AgentID = iDRAC
Severity = Warning
Timestamp = 2020-06-20 03:19:21
Message = Error occurred on Disk 2 in Backplane 1 of Integrated RAID Controller 1 : (Error f0).
Message Arg 1 = Disk 2 in Backplane 1 of Integrated RAID Controller 1
Message Arg 2 = (Error f0)
FQDD = Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
--------------------------------------------------------------------------------
SeqNumber = 167
Message ID = VDR8
Category = Storage
AgentID = iDRAC
Severity = Warning
Timestamp = 2020-06-20 03:19:21
Message = Virtual Disk 0 on Integrated RAID Controller 1 is degraded either because the physical disk drive in the drive group is removed or the physical disk drive added in a redundant virtual drive has failed.
Message Arg 1 = Virtual Disk 0 on Integrated RAID Controller 1
FQDD = Disk.Virtual.0:RAID.Integrated.1-1
--------------------------------------------------------------------------------
SeqNumber = 166
Message ID = PDR3
Category = Storage
AgentID = iDRAC
Severity = Critical
Timestamp = 2020-06-20 03:19:21
Message = Disk 2 in Backplane 1 of Integrated RAID Controller 1 is not functioning correctly.
Message Arg 1 = Disk 2 in Backplane 1 of Integrated RAID Controller 1
FQDD = Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1
--------------------------------------------------------------------------------
SeqNumber = 165
Message ID = LOG007
Category = Audit
AgentID = DE
Severity = Information
Timestamp = 2020-06-20 03:19:21
Message = The previous log entry was repeated 1 times.
Message Arg 1 = 1
--------------------------------------------------------------------------------
SeqNumber = 164
Message ID = PDR87
Category = Storage
AgentID = iDRAC
Severity = Information
Timestamp = 2020-06-20 03:19:06
Message = Disk 2 in Backplane 1 of Integrated RAID Controller 1 was reset.
Message Arg 1 = Disk 2 in Backplane 1 of Integrated RAID Controller 1
FQDD = Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1