smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-10-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SSDSC2KB019T8R
Serial Number: PHYF917601PP1P9DGN
LU WWN Device Id: 5 5cd2e4 150dbd9dd
Add. Product Id: DELL(tm)
Firmware Version: XCV1DL63
User Capacity: 1,920,383,410,176 bytes [1.92 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Feb 19 08:51:24 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
Conveyance self-test routine
recommended polling time: ( 60) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000e 130 130 039 Old_age Always - 4294967295
5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 13522
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27
13 Read_Soft_Error_Rate 0x001e 088 088 000 Old_age Always - 281474976710655
170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0
174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 25
179 Used_Rsvd_Blk_Cnt_Tot 0x0033 100 100 010 Pre-fail Always - 0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 14741
181 Program_Fail_Cnt_Total 0x003a 100 100 000 Old_age Always - 0
182 Erase_Fail_Count_Total 0x003a 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 24
195 Hardware_ECC_Recovered 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 16514
201 Unknown_SSD_Attribute 0x0033 100 100 010 Pre-fail Always - 120259021426
202 Unknown_SSD_Attribute 0x0027 100 100 000 Pre-fail Always - 0
225 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 1167544
226 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 389
227 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 59
228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 811163
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 1167544
234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 1167544
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 1731053
245 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 100
SMART Error Log not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Read SMART Selective Self-test Log failed: megasas_cmd result: 0.1 = 0/45

Event Timeline

ProdPasteBot changed the title of this paste from untitled to Masterwork From Distant Lands.