Temperature properties don't display conversion for default Celsius
Closed, ResolvedPublic

Description

Author: info

Description:
If you enter

[[temperature test::-40 Celsius]]

SMW 1.0-RC3 just shows the temperature, it doesn't show a tooltip with the conversions nor does it show the temperature normalized to K with other values in parentheses in the factbox.

This is a change from 0.7 behavior, which always showed the conversion.

The test page also shows some weirdness with bad or dubious temperature values such as

[[temperature test::-43F]]

, they don't output any errors.


Version: unspecified
Severity: normal
URL: http://ontoworld.org/wiki/SMW_unit_test:Test_temperature

Details

Reference
bz12379

Event Timeline

bzimport raised the priority of this task from to Medium.Nov 21 2014, 9:59 PM
bzimport set Reference to bz12379.

info wrote:

switch on right variable, also remove unneeded case and addError (review!)

I don't trust Eclipse Create patch on Windows, here's the patch.

Note the last change: should SMW be aggressive on bad units or flexible?

Index: C:/xampplite/htdocs/mediawiki/extensions/SemanticMediaWiki/includes/SMW_DV_Temperature.php

  • C:/xampplite/htdocs/mediawiki/extensions/SemanticMediaWiki/includes/SMW_DV_Temperature.php (revision 28741)

+++ C:/xampplite/htdocs/mediawiki/extensions/SemanticMediaWiki/includes/SMW_DV_Temperature.php (working copy)
@@ -27,7 +27,7 @@

		// Find current ID and covert main values to Kelvin, if possible
		// Note: there is no error when unknown units are used.
		$this->m_unitin = $this->getUnitID($this->m_unit);
  • switch ( $this->m_unit ) {

+ switch ( $this->m_unitin ) {

			case 'K':
				$this->m_unit = 'K';
			break;

@@ -35,7 +35,7 @@

				$this->m_unit = 'K';
				$this->m_value = $this->m_value + 273.15;
			break;
  • case '°F': case 'Fahrenheit':

+ case '°F':

				$this->m_unit = 'K';
				$this->m_value = ($this->m_value - 32) /1.8 + 273.15;
			break;

@@ -40,6 +40,10 @@

				$this->m_value = ($this->m_value - 32) /1.8 + 273.15;
			break;
			default: //unsupported unit

+ TODO: Should this be an error? Without addError(), SMW displays
+
and stores your temperature, but doesn't convert it.
+ // Maybe have an addWarning()?
+ $this->addError(wfMsgForContent('smw_unsupportedunit',$this->m_unit));

				$this->m_unit = $this->m_unitin;
			break;
		}

Attached: