Degraded RAID on db2044
Closed, ResolvedPublic

Description

TASK AUTO-GENERATED by Nagios/Icinga RAID event handler

A degraded RAID (hpssacli) was detected on host db2044. An automatic snapshot of the current RAID status is attached below.

Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.

Smart Array P420i in Slot 0 (Embedded)

   array A

      Logical Drive: 1
         Size: 3.3 TB
         Fault Tolerance: 1+0
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 65535
         Strip Size: 256 KB
         Full Stripe Size: 1536 KB
         Status: Interim Recovery Mode
         Caching:  Enabled
         Unique Identifier: 600508B1001CFDE21428C616A77DCA1C
         Disk Name: /dev/sda 
         Mount Points: / 37.3 GB Partition Number 2
         OS Status: LOCKED
         Logical Drive Label: A41E15230014380337F5EF0627E
         Mirror Group 1:
            physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
            physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
            physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
            physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
            physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
            physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
         Mirror Group 2:
            physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
            physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
            physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
            physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
            physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, Failed)
            physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)
         Drive Type: Data
         LD Acceleration Method: Controller Cache

Event Timeline

Marostegui added a project: DBA.
Marostegui added subscribers: Papaul, Marostegui.

Hi @Papaul - please change the disk once you have time for it!
Thanks!

Papaul triaged this task as Medium priority.Mar 6 2017, 3:53 PM

Dear Mr Papaul Tshibamba,

Thank you for contacting Hewlett Packard Enterprise for your service request. This email confirms your request for service and the details are below.

Your request is being worked on under reference number 5317789754
Status: Case is generated and in Progress

Product description: HP ProLiant DL380p Gen8 12 LFF Configure-to-order Server
Product number: 665552-B21
Serial number: 2M245205HG
Subject: DL380p Gen8 - HDD failure

Yours sincerely,
Hewlett Packard Enterprise

Thanks! Disk is rebuilding!

root@db2044:~# hpssacli controller all show config

Smart Array P420i in Slot 0 (Embedded)    (sn: 0014380337F5EF0)


   Port Name: 1I

   Port Name: 2I

   Gen8 ServBP 12+2 at Port 1I, Box 1, OK
   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (3.3 TB, RAID 1+0, Recovering, 7% complete)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
      physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
      physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
      physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
      physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
      physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
      physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
      physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, Rebuilding)
      physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)

All good now, thanks

logicaldrive 1 (3.3 TB, RAID 1+0, OK)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)