TASK AUTO-GENERATED by Nagios/Icinga RAID event handler
A degraded RAID (megacli) was detected on host ms-be1006. An automatic snapshot of the current RAID status is attached below.
Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.
=== RaidStatus (does not include components in optimal state) name: Adapter #0 Virtual Drive: 9 (Target Id: 9) RAID Level: Primary-0, Secondary-0, RAID Level Qualifier-0 State: =====> Offline <===== Number Of Drives: 1 Number of Spans: 1 Current Cache Policy: WriteThrough, ReadAheadNone, Direct, Write Cache OK if Bad BBU Span: 0 - Number of PDs: 1 PD: 0 Information Enclosure Device ID: 32 Slot Number: 9 Drive's position: DiskGroup: 8, Span: 0, Arm: 0 Media Error Count: 0 Other Error Count: 41 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 Raw Size: 1.819 TB [0xe8e088b0 Sectors] Firmware state: =====> Failed <===== Media Type: Hard Disk Device Drive Temperature: 33C (91.40 F) === RaidStatus completed