Page MenuHomePhabricator

Degraded RAID on ms-be1006
Closed, ResolvedPublic

Description

TASK AUTO-GENERATED by Nagios/Icinga RAID event handler

A degraded RAID (megacli) was detected on host ms-be1006. An automatic snapshot of the current RAID status is attached below.

Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.

=== RaidStatus (does not include components in optimal state)
name: Adapter #0

	Virtual Drive: 9 (Target Id: 9)
	RAID Level: Primary-0, Secondary-0, RAID Level Qualifier-0
	State: =====> Offline <=====
	Number Of Drives: 1
	Number of Spans: 1
	Current Cache Policy: WriteThrough, ReadAheadNone, Direct, Write Cache OK if Bad BBU

		Span: 0 - Number of PDs: 1

			PD: 0 Information
			Enclosure Device ID: 32
			Slot Number: 9
			Drive's position: DiskGroup: 8, Span: 0, Arm: 0
			Media Error Count: 0
			Other Error Count: 41
			Predictive Failure Count: 0
			Last Predictive Failure Event Seq Number: 0

				Raw Size: 1.819 TB [0xe8e088b0 Sectors]
				Firmware state: =====> Failed <=====
				Media Type: Hard Disk Device
				Drive Temperature: 33C (91.40 F)

=== RaidStatus completed

Event Timeline

Volans updated the task description. (Show Details)
Volans added a subscriber: fgiunchedi.
MoritzMuehlenhoff triaged this task as Medium priority.

I've also ACK'ed on Icinga the related puppet run alarm