Degraded RAID on db1073
Closed, ResolvedPublic

Description

TASK AUTO-GENERATED by Nagios/Icinga RAID event handler

A degraded RAID (megacli) was detected on host db1073. An automatic snapshot of the current RAID status is attached below.

Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.

CRITICAL: 1 failed LD(s) (Degraded)

$ sudo /usr/local/lib/nagios/plugins/get_raid_status_megacli
=== RaidStatus (does not include components in optimal state)
name: Adapter #0

	Virtual Drive: 0 (Target Id: 0)
	RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
	State: =====> Degraded <=====
	Number Of Drives per span: 2
	Number of Spans: 6
	Current Cache Policy: WriteBack, ReadAhead, Direct, No Write Cache if Bad BBU

		Span: 3 - Number of PDs: 2

			PD: 1 Information
			Enclosure Device ID: 32
			Slot Number: 7
			Drive's position: DiskGroup: 0, Span: 3, Arm: 1
			Media Error Count: 2
			Other Error Count: 6
			Predictive Failure Count: 0
			Last Predictive Failure Event Seq Number: 0

				Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
				Firmware state: =====> Failed <=====
				Media Type: Hard Disk Device
				Drive Temperature: 39C (102.20 F)

=== RaidStatus completed

Related Objects

Event Timeline

Marostegui triaged this task as High priority.
Marostegui added a project: DBA.
Marostegui added a subscriber: Cmjohnson.

This is m5 master
@Cmjohnson do you have an used disk somewhere to replace this one? Thanks!

Disk replaced and rebuilding

Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Rebuild
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up

All good!
Thanks a lot!

root@db1073:~#  megacli -LDInfo -L0 -a0


Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-1, Secondary-0, RAID Level Qualifier-0
Size                : 3.271 TB
Sector Size         : 512
Mirror Data         : 3.271 TB
State               : Optimal
Strip Size          : 256 KB