TASK AUTO-GENERATED by Nagios/Icinga RAID event handler
A degraded RAID (hpssacli) was detected on host cloudvirt1019. An automatic snapshot of the current RAID status is attached below.
Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.
CRITICAL: Slot 1: Failed: 1I:1:5, 1I:1:6, 1I:1:7, 1I:1:8 - OK: 2I:1:1, 2I:1:2, 2I:1:3, 2I:1:4, 2I:2:1, 2I:2:2 - Controller: OK - Battery/Capacitor: Recharging
$ sudo /usr/local/lib/nagios/plugins/get_raid_status_hpssacli
Smart Array P840 in Slot 1
array A
Logical Drive: 1
Size: 7.3 TB
Fault Tolerance: 1+0
Strip Size: 256 KB
Full Stripe Size: 1280 KB
Status: Interim Recovery Mode
MultiDomain Status: OK
Caching: Disabled
Disk Name: /dev/sda
Mount Points: / 85.7 GB Partition Number 2
OS Status: LOCKED
Mirror Group 1:
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, Solid State SATA, 1600.3 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 0 MB, Failed)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 0 MB, Failed)
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 0 MB, Failed)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 0 MB, Failed)
Mirror Group 2:
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, Solid State SATA, 1600.3 GB, OK)
physicaldrive 2I:1:3 (port 2I:box 1:bay 3, Solid State SATA, 1600.3 GB, OK)
physicaldrive 2I:1:4 (port 2I:box 1:bay 4, Solid State SATA, 1600.3 GB, OK)
physicaldrive 2I:2:1 (port 2I:box 2:bay 1, Solid State SATA, 1600.3 GB, OK)
physicaldrive 2I:2:2 (port 2I:box 2:bay 2, Solid State SATA, 1600.3 GB, OK)
Drive Type: Data
LD Acceleration Method: HPE SSD Smart Path