Page MenuHomePhabricator

Disk error on db1063
Closed, DeclinedPublic

Description

We have a failed disk in db1063. The host is master for m1 database cluster.
We need a disk replacement

name: Adapter #0

	Virtual Drive: 0 (Target Id: 0)
	RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
	State: Optimal
	Number Of Drives per span: 2
	Number of Spans: 6
	Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU

		Span: 3 - Number of PDs: 2

			PD: 1 Information
			Enclosure Device ID: 32
			Slot Number: 7
			Drive's position: DiskGroup: 0, Span: 3, Arm: 1
			Media Error Count: 2
			Other Error Count: 0
			Predictive Failure Count: =====> 1 <=====
			Last Predictive Failure Event Seq Number: 2776

				Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
				Firmware state: Online, Spun Up
				Media Type: Hard Disk Device
				Drive Temperature: 34C (93.20 F)

Event Timeline

Banyek created this task.Dec 3 2018, 8:15 AM
Restricted Application added a subscriber: Aklapper. · View Herald TranscriptDec 3 2018, 8:15 AM
Banyek triaged this task as Normal priority.Dec 3 2018, 8:15 AM
Banyek updated the task description. (Show Details)

I thought we agreed on not replacing disks till they are finally failed and only add them to: T208323 ?

Banyek closed this task as Declined.Dec 3 2018, 9:15 AM

We don't deal with this until actual failiure