TASK AUTO-GENERATED by Nagios/Icinga RAID event handler
A degraded RAID (hpssacli) was detected on host db2059. An automatic snapshot of the current RAID status is attached below.
Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.
CRITICAL: Slot 0: OK: 1I:1:1, 1I:1:10, 1I:1:11, 1I:1:2, 1I:1:3, 1I:1:4, 1I:1:5, 1I:1:6, 1I:1:7, 1I:1:8, 1I:1:9 - Failed: 1I:1:12 - Controller: OK - Battery/Capacitor: OK
$ sudo /usr/local/lib/nagios/plugins/get-raid-status-hpssacli
Smart Array P420i in Slot 0 (Embedded)
array A
Logical Drive: 1
Size: 3.3 TB
Fault Tolerance: 1+0
Strip Size: 256 KB
Full Stripe Size: 1536 KB
Status: Interim Recovery Mode
Caching: Enabled
Disk Name: /dev/sda
Mount Points: / 37.3 GB Partition Number 2
OS Status: LOCKED
Mirror Group 1:
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
Mirror Group 2:
physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, OK)
physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, Failed)
Drive Type: Data
LD Acceleration Method: Controller Cache