Page MenuHomePhabricator

Degraded RAID on db2067
Closed, ResolvedPublic

Description

TASK AUTO-GENERATED by Nagios/Icinga RAID event handler

A degraded RAID (hpssacli) was detected on host db2067. An automatic snapshot of the current RAID status is attached below.

Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.

CRITICAL: Slot 0: Failed: 1I:1:1 - OK: 1I:1:10, 1I:1:11, 1I:1:12, 1I:1:2, 1I:1:3, 1I:1:4, 1I:1:5, 1I:1:6, 1I:1:7, 1I:1:9 - Predictive Failure: 1I:1:8 - Controller: OK - Battery/Capacitor: OK

$ sudo /usr/local/lib/nagios/plugins/get-raid-status-hpssacli

Smart Array P420i in Slot 0 (Embedded)

   array A

      Logical Drive: 1
         Size: 3.3 TB
         Fault Tolerance: 1+0
         Strip Size: 256 KB
         Full Stripe Size: 1536 KB
         Status: Interim Recovery Mode
         Caching:  Enabled
         Disk Name: /dev/sda 
         Mount Points: / 37.3 GB Partition Number 2
         OS Status: LOCKED
         Mirror Group 1:
            physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, Failed)
            physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
            physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
            physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
            physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
            physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
         Mirror Group 2:
            physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
            physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, Predictive Failure)
            physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
            physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
            physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
            physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)
         Drive Type: Data
         LD Acceleration Method: Controller Cache

Event Timeline

Marostegui added a project: DBA.
Marostegui added a subscriber: Papaul.

@Papaul can we replace the failed disk with a brand new one?
This host is scheduled for decommission, but we have to buy its replacement first (T234608)

Marostegui moved this task from Triage to In progress on the DBA board.

Thanks!

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, Rebuilding)

Rebuilt finished

root@db2067:~# hpssacli controller all show config

Smart Array P420i in Slot 0 (Embedded)    (sn: 0014380337F5F00)


   Port Name: 1I

   Port Name: 2I

   Gen8 ServBP 12+2 at Port 1I, Box 1, OK
   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (3.3 TB, RAID 1+0, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 600 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 600 GB, OK)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 600 GB, OK)
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 600 GB, OK)
      physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 600 GB, OK)
      physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 600 GB, OK)
      physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 600 GB, OK)
      physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 600 GB, Predictive Failure)
      physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 600 GB, OK)
      physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK)
      physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK)
      physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK)

Let's not change the one on predictive failure until it finally fails.