We are receiving an alert about the state of the RAID array on an-worker1082.
We saw a very similar alert recently in T308267 from an almost identical server.
We are receiving an alert about the state of the RAID array on an-worker1082.
We saw a very similar alert recently in T308267 from an almost identical server.
| Status | Subtype | Assigned | Task | ||
|---|---|---|---|---|---|
| Resolved | BTullis | T311991 RAID battery alert in an-worker1082 | |||
| Resolved | BTullis | T312626 Replace RAID controller battery in an-worker1082 |
The battery is not currently being charged and has a very low state of charge.
btullis@an-worker1082:~$ sudo megacli -AdpBbuCmd -aALL BBU status for Adapter: 0 BatteryType: BBU Battery State: Unknown Battery backup charge time : 0 hours BBU Capacity Info for Adapter: 0 Relative State of Charge: 8 % Absolute State of charge: 0 % Remaining Capacity: 47 mAh Full Charge Capacity: 662 mAh Run time to empty: Battery is not being charged. Average time to empty: 4 Min. Estimated Time to full recharge: Battery is not being charged. Cycle Count: 2 Max Error = 0 % Remaining Capacity Alarm = 0 mAh Remining Time Alarm = 0 Min BBU Design Info for Adapter: 0 Date of Manufacture: 00/00, 0000 Design Capacity: 460 mAh Design Voltage: 0 mV Specification Info: 0 Serial Number: 0 Pack Stat Configuration: 0x0000 Manufacture Name: 0x113 Firmware Version : 0.6 Device Name: Device Chemistry: Battery FRU: N/A Module Version = 0.6 Transparent Learn = 1 App Data = 1 BBU Properties for Adapter: 0 Auto Learn Period: 90 Days Next Learn time: None Learn Delay Interval:0 Hours Auto-Learn Mode: Disabled Exit Code: 0x00
I will see what I can do in terms of getting it to charge.
@Volans: this is not a duplicate. This task is for the service owner and the subtask is the repair ticket for DC-Ops.