Page MenuHomePhabricator

RAID battery alert in an-worker1082
Closed, ResolvedPublic

Description

We are receiving an alert about the state of the RAID array on an-worker1082.

We saw a very similar alert recently in T308267 from an almost identical server.

Event Timeline

The battery is not currently being charged and has a very low state of charge.

btullis@an-worker1082:~$ sudo megacli -AdpBbuCmd -aALL

BBU status for Adapter: 0

BatteryType: BBU
Battery State: Unknown
  Battery backup charge time : 0 hours

BBU Capacity Info for Adapter: 0

  Relative State of Charge: 8 %
  Absolute State of charge: 0 %
  Remaining Capacity: 47 mAh
  Full Charge Capacity: 662 mAh
  Run time to empty: Battery is not being charged.
  Average time to empty: 4 Min.
  Estimated Time to full recharge: Battery is not being charged.
  Cycle Count: 2
Max Error = 0 %
Remaining Capacity Alarm = 0 mAh
Remining Time Alarm = 0 Min

BBU Design Info for Adapter: 0

  Date of Manufacture: 00/00, 0000
  Design Capacity: 460 mAh
  Design Voltage: 0 mV
  Specification Info: 0
  Serial Number: 0
  Pack Stat Configuration: 0x0000
  Manufacture Name: 0x113
  Firmware Version   : 0.6
  Device Name:
  Device Chemistry:
  Battery FRU: N/A
Module Version = 0.6
  Transparent Learn = 1
  App Data = 1

BBU Properties for Adapter: 0

  Auto Learn Period: 90 Days
  Next Learn time: None  Learn Delay Interval:0 Hours
  Auto-Learn Mode: Disabled

Exit Code: 0x00

I will see what I can do in terms of getting it to charge.

RhinosF1 added a subscriber: Volans.

@Volans: this is not a duplicate. This task is for the service owner and the subtask is the repair ticket for DC-Ops.