Dell SSD Critical Firmware Update
Closed, ResolvedPublic

Description

Dell released a 'Critical Firmware Update' announcement for enterprise-grade Youngsville chipset based SSDs.

The following hosts are affected:
T396649:
frbackup2002 7G6ZWP3 https://netbox.wikimedia.org/dcim/devices/4180/

T396648:
db1250 9GLPW54 https://netbox.wikimedia.org/dcim/devices/5735/
db1251 DGLPW54 https://netbox.wikimedia.org/dcim/devices/5736/
db1252 BGLPW54 https://netbox.wikimedia.org/dcim/devices/5737/
db1253 CGLPW54 https://netbox.wikimedia.org/dcim/devices/5738/
db1254 8GLPW54 https://netbox.wikimedia.org/dcim/devices/5739/

T394432 :
cirrussearch2110 C76YW54 https://netbox.wikimedia.org/dcim/devices/5645/
cirrussearch2111 D76YW54 https://netbox.wikimedia.org/dcim/devices/5646/
cirrussearch2112 F76YW54 https://netbox.wikimedia.org/dcim/devices/5647/
cirrussearch2113 J76YW54 https://netbox.wikimedia.org/dcim/devices/5648/
cirrussearch2114 G76YW54 https://netbox.wikimedia.org/dcim/devices/5649/
cirrussearch2115 H76YW54 https://netbox.wikimedia.org/dcim/devices/5650/

T394498:
52JZYS3 - an-mariadb1001
42JZYS3 - an-mariadb1002

T394499
72JZYS3 - an-coord1003
62JZYS3 - an-coord1004

T396651
B0SMY24 - cloudcephosd1035
80SMY24 - cloudcephosd1036
70SMY24 - cloudcephosd1037
90SMY24 - cloudcephosd1038
GX6VY24 - cloudcephosd1039
HX6VY24 - cloudcephosd1040
JX6VY24 - cloudcephosd1041

“DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.

Needs firmware DL7C (or later)

Announcement Email

T394348#10823828

Procedure

At the time of this task filing, the firmware update has not been rolled out within WMF. We are not sure if it can be performed with the system remaining online, but most firmware updates require a reboot so we should operate with the understanding a reboot will be required and downtime scheduled.

  • firmware update uploaded to both cumin1002 and cumin2002
  • update tested on one of the list before the rest are rolled out to see if it can operate with system online or if it requires reboot
  • update and file tasks for remainder of hosts with detailed checklist pending result of first tested update

proposed checklist

  • - schedule downtime for host with service owners and icinga
  • - note old firmware version
  • - send firmware update cumin cookbook command: cookbook sre.hardware.upgrade-firmware -c ssd "hostname*" and select option 0 for DL7C.
  • - confirm firmware updated to correct version on all affected SSDs
  • - pass system back to service owners/service use

Event Timeline

RobH triaged this task as High priority.

Pasting the email body into a comment so folks don't have to read it in the task description:

Customer Advisory Regarding Dell Technologies Enterprise Systems with specific Youngsville solid state drives (SSDs) which may have a higher than expected incident rate of SSDs going offline and requiring replacement if the firmware is not updated.

(Dell Technologies Internal Reference ID - Dell Technologies ET-5208)
This Customer Advisory is to inform you of an issue involving certain Dell Technologies Enterprise Systems with specific Youngsville SSDs which may have higher than expected incident rates of SSDs going offline and requiring replacement if the firmware is not updated.
As a result of this issue, Dell Technologies is highly recommending running a minimum firmware version of DL7A in order to maintain optimal system performance and to help prevent experiencing this issue.
If you are running a firmware version older than DL7A, Dell highly recommends an immediate upgrade of all impacted Youngsville family of SSDs to the latest available firmware version supported by your specific enterprise product.
Although you may not have encountered the issue described in this Customer Advisory, Dell Technologies strongly recommends that you perform the suggested firmware upgrade(s) as soon as possible.
The following Youngsville SSDs are covered under this notice:
Dell Part Number Family Capacity Model Firmware Version
GHD66 Youngsville 240GB SSDSC2KB240GZR Older than DL7A
CM88M Youngsville 240GB SSDSCKKB240GZR Older than DL7A
M7F5D Youngsville 480GB SSDSCKKB480GZR Older than DL7A
GX439 Youngsville 480GB SSDSC2KB480GZR Older than DL7A
53KHR Youngsville 480GB SSDSC2KB480GZR Older than DL7A
00DJ5 Youngsville 480GB SSDSC2KG480GZR Older than DL7A
D5C1D Youngsville 480GB SSDSC2KG480GZR Older than DL7A
5M8Y4 Youngsville 960GB SSDSC2KB960GZR Older than DL7A
F6H8H Youngsville 960GB SSDSC2KB960GZR Older than DL7A
8MHYH Youngsville 960GB SSDSC2KG960GZR Older than DL7A
DYMD0 Youngsville 960GB SSDSC2KG960GZR Older than DL7A
6J65H Youngsville 1.92TB SSDSC2KB019TZR Older than DL7A
VYYW8 Youngsville 1.92TB SSDSC2KB019TZR Older than DL7A
6XW3M Youngsville 1.92TB SSDSC2KG019TZR Older than DL7A
8RXV5 Youngsville 1.92TB SSDSC2KG019TZR Older than DL7A
WNPN1 Youngsville 3.84TB SSDSC2KB038TZR Older than DL7A
7KDJJ Youngsville 3.84TB SSDSC2KG038TZR Older than DL7A
572Y6 Youngsville 3.84TB SSDSC2KG038TZR Older than DL7A
KM4C4 Youngsville 3.84TB SSDSC2KB038TZR Older than DL7A
XKP9T Youngsville 7.68TB SSDSC2KB076TZR Older than DL7A
Although you may not have encountered the issue described in this Customer Advisory, Dell Technologies strongly recommends that you perform the suggested firmware update.
Implementation Procedure:
One or more of your Dell Technologies Enterprise System(s) may be affected by this issue.
Service Tag(s): 7G6ZWP3, 8GLPW54, 9GLPW54, BGLPW54, C76YW54, CGLPW54, D76YW54, DGLPW54, F76YW54, G76YW54, H76YW54, J76YW54
Dell always recommends applying the latest available firmware qualified for your product platform.
Please locate the latest Youngsville SSD firmware using the recommended method below:
Dell PowerEdge or OEM PowerEdge Servers with impacted Youngsville SSDs:
As of March 2025, the latest qualified Youngsville SSDs firmware version supported on the PowerEdge Server platform is version DL7C. To located and install firmware version DL7C please refer to the instructions below.
Dell PowerEdge Server Platform or Service Tag Search Option:

Go to https://www.dell.com/support
Input your service tag and click search or click browse to your product by clicking Infrastructure -> Servers -> PowerEdge -> PowerEdge Server Type (Rack, Tower, etc.) -> and choosing your specific server model. (e.g. R650)
Go to “Drivers & Downloads”.
Choose your applicable Operating System and SSD firmware update.
Keyword search for “Youngsville”.
Download Firmware version DL7C (or later)

“DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.

Follow the instructions to install the updated Youngsville SSD firmware.

In the rare event your Dell PowerEdge Server Service Tag or Platform Model does not have DL7C firmware available when looking up your service tag or in the product support page, please find the applicable firmware by searching for the firmware identification code number(s) below.

Go to https://www.dell.com/support
In the search field input either the driver version “DL7C” or the driver code “VJPKG”. In the search results click on “DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”
Download firmware and follow the instructions to install the updated Youngsville SSD firmware.

While Dell always recommends applying the latest available firmware update for you platform, if your organizations change management policy requires not installing the latest release, the minimum recommended firmware version of DL7A can be located below.

Go to https://www.dell.com/support

In the search field input the driver version “DL7A” or the driver code “9RF8X”.

In the search results click on “Intel Youngsville-RR DL7A for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.. | Driver Details”.

Dell XC Appliance and Core Systems with impacted Youngsville SSDs:
For Dell XC Systems equipped with Youngsville SSDs and utilizing Nutanix Life Cycle Manager (LCM):
Dell highly recommends utilizing the LCM to verify which firmware is currently installed, and to update your Youngsville SSD firmware on your XC Series Appliances and XC Core Systems. The LCM is designed to automate the process while maintaining redundancy to your Nutanix cluster.
Please use the link below to utilize the LCM to verify which drive firmware revision is currently installed and to update your firmware:

Dell XC Core System Life Cycle Manager Reference Guide: LCM Update

https://www.dell.com/support/manuals/en-us/dell-xc630/xc-appliance-core-lcm_refg/update-lcm?guid=guid-2fbb494a-3bda-4f33-84ca-62fb3072df8d
https://dl.dell.com/content/manual57539163-dell-xc-series-appliance-and-xc-core-system-life-cycle-manager-reference-guide.pdf

For XC Systems equipped with Youngsville SSDs, and not utilizing LCM:
If LCM is not preferred in your XC environment, the latest Youngsville SSD firmware update for XC Series Appliances and XC Core Systems is available on dell.com/support.
To implement drive firmware updates, use the following manual and cluster-safe process.
The below links advise how to safely shutdown a node based on the hypervisor they are running.
It is critical these steps be followed in order to maintain cluster health.

Shutting Down a Node in a Cluster (AHV Hypervisor):

https://portal.nutanix.com/page/documents/details?targetId=AHV-Admin-Guide-v10_0:ahv-node-shutdown-ahv-t.html
Shutting Down a Node in a Cluster (vSphere Hypervisor):

https://portal.nutanix.com/page/documents/details?targetId=vSphere-Admin6-AOS-v5_17%3ANode%20Management
Shutting Down a Node in a Cluster (Hyper-V Hypervisor):

https://portal.nutanix.com/page/documents/details?targetId=HyperV-Admin-AOS-v7_0:hyp-node-shutdown-hyperv-t.html

Once the node is shutdown follow the steps below for downloading and updating the drive firmware.

Go to https://www.dell.com/support
Input your service tag and click search or click browse to your product by clicking Infrastructure -> Converged Infrastructure -> Hyper-converged Systems -> XC Core or XC Appliance Systems -> and choosing your specific server model. (e.g. XC740XD2 CORE)
Go to “Drivers & Downloads”.
Choose your applicable Operating System.
Keyword search for “Youngsville”.
Download Firmware version DL7A*
  • The latest Youngsville SSD firmware qualified on XC products at the time of this notification is DL7A. Please refer to the supported platforms section of any subsequent Youngsville firmware release to determine if XC products are qualified for an updated release.

“Intel Youngsville-RR DL7A for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.

Follow the instructions to install the updated Youngsville SSD firmware.
Once the SSD firmware is updated on the node, bring that node back online.
Once the node is back online, move to the next node in the cluster and follow the shutdown and download process above until all nodes are updated.
In a XC cluster environment, only one XC node should be updated at a time.

In the event your Dell XC Appliance and Core System Service Tag or Platform Model does not have the firmware available when looking up your service tag or in the product support page, please find the applicable firmware by searching for the firmware identification code number(s) below.

Go to https://www.dell.com/support

In the search field input the driver version “DL7A” or the driver code “9RF8X”..

In the search results click on “Intel Youngsville-RR DL7A for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.. | Driver Details”.

Dell EMC AzureStack HCI (S2D Ready Nodes and AX Nodes) firmware update instructions:

Azure Stack HCI firmware and driver updates can be performed in three methods:
    Windows Admin Center
    iDRAC out-of-band method
    In-band method
    SBE(Solution Builder Extension) – only for 23H2 based clusters
All three methods can be used to update to update Firmware to the latest versions listed per the Support Matrix:

https://dell.github.io/azurestack-docs/docs/hci/supportmatrix/
Dell EMC AzureStack HCI Update Method (1) and (2)
Update Method 1 and 2 are described in the Microsoft HCI Solutions from Dell Technologies End to End deployment and operations Guide: via the link below:
Microsoft HCI Solutions from Dell Technologies End to End deployment and Operations Guide with Scalable Networking:
https://infohub.delltechnologies.com/t/e2e-deployment-and-operations-guide-with-scalable-networking-microsoft-hci-solutions-from-dell-technologies-1/
Method (1): (Windows Admin Center)

Refer to section Viewing update compliance and updating the cluster beginning on page 56 of the Microsoft HCI Solutions from Dell Technologies End to End deployment and Operations Guide with Scalable Networking:

Method (2): (iDRAC out-of-band)

Refer to section Firmware and driver updates using the manual method beginning on page 76 of the Microsoft HCI Solutions from Dell Technologies End to End deployment and operations Guide:

Method (3): in-band procedure is a manual way to update individual DUPs:

Go to https://www.dell.com/support
In the search field input the driver version “DL7A” or the driver code “9RF8X”.
In the search results click on “Intel Youngsville-RR DL7A for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR”.. | Driver Details”.
Download Firmware version DL7A*
  • The latest Youngsville SSD firmware qualified on Azure Stack HCI AX products at the time of this notification is DL7A. Please refer to the supported platforms section of any subsequent Youngsville firmware release to determine if XC products are qualified for an updated release.

    Place the node identified for the update into maintenance mode.

Refer to section Preparing for maintenance operations and Placing an S2D Ready Node or AX node in maintenance mode under Firmware and driver updates using the manual method beginning on page 76 of the Microsoft HCI Solutions from Dell Technologies End to End deployment and operations Guide to put the node into maintenance mode.

Run Serial-ATA_Firmware_9RF8X_WN64_DL7A_A00.EXE with elevated mode to complete the update.

Remove the updated node from maintenance mode.

Refer to section Exiting the AX node from maintenance mode under Firmware and driver updates using the manual method of beginning on page 79 of the Microsoft HCI Solutions from Dell Technologies Operations Guide to get the node out of the maintenance mode.

Repeat the above steps on the next node in the cluster if applicable.

Method (4): Using Solution Builder Extension (SBE)

This method is applicable for the Azure stack HCI clusters version 23H2, refer the KB article for the install instruction https://www.dell.com/support/kbdoc/en-us/000224407
Recommendation and Further Assistance
Dell recommends that you regularly install the latest software and system updates as part of standard computing practices to maintain system performance and security. If you decide not to install this critical update now, know that these products may encounter higher than expected incident rates of SSDs going offline and requiring replacement if the Youngsville SSD firmware is not updated.
If you need assistance or have any other questions, please contact Dell Technologies Technical Support. Dell Technologies provides several online and telephone-based support and services options. Availability varies by country and product, and some services may not be available in your area. To contact Dell Technologies for sales, technical support, or customer service issues please visit:

https://www.dell.com/support
Select the contact method that best suits your needs.
Please reference Knowledge Base Article 000226989 if regarding this notice.

Dell Technologies appreciates your business. We are constantly working to help customers better protect their most important asset: their business data.
Thank you for choosing Dell Technologies.

RobH updated the task description. (Show Details)

@Gehel: cirrussearch2110[0-5] are affected by this firmware update and will need to be updated. However, I'm not sure if the update can be applied with the host online, or if it will require reboot. Would you be able to free up one of these 6 for me to test the firmware update before I document SSD firmware upgrades and create a checklist for the rest of them?

We should plan for full downtime on the test host in case I cannot do it with it online, but I'll test an 'OS Online' update first and see if it will work. If it does, it simplifies updating the rest of the cirrussearch211[0-5] hosts and all the affected DB hosts. I just rather test on cirrussearch first since it is less SSDs overall per host (2) than the db hosts (10).

@RobH we're in the process of migrating from Elasticsearch to OpenSearch on that cluster. We should be good to get a host or 2 out of the cluster for experimentation, but please coordinate with @bking or @RKemper.

I've created sub-task T392935 to track cirrussearch maint windows, likely should have just done that to start but was hoping one was just easily kicked offline for testing.

This task can be used to track the overall procedure, and the sub-task T392935 used for individual server scheduling.

Just wondering @RobH, why do an-coord100[3-4] say (decommissioned) ?

Just wondering @RobH, why do an-coord100[3-4] say (decommissioned) ?

@wiki_willy: Please advise, I wasn't sure why the list you sent me had this note by these two hosts either, but they are not decom it seems?

Hi @BTullis - apologies for the mixup. For some reason, I had mixed up the dates with an-coord100[1,2], which are both offline. I've fixed the notes and removed the (decommissioned) part. Thanks for catching that!

The firmware directory on the cumin hosts has a STORAGE directory, but the cookbook has a failure documented on T394543 for repair before we can roll out the firmware upgrade easily to the affected hosts.

A reboot is required for this firmware update.

Icinga downtime and Alertmanager silence (ID=7389739c-a74e-4785-99a6-55575ec65f75) set by bking@cumin2002 for 7 days, 0:00:00 on 1 host(s) and their services with reason: firmware update cookbook

cirrussearch2110.codfw.wmnet

The cookbook has been repaired via T394543 (Thank you Riccardo!) and now sub-tasks have been filed and linked from this parent task for all service groups/sre sub-teams update of hosts.

All affected servers (except an-mariadb1001) have been taken care of via their various sub-tasks. Followed up on the specific linked task for that host directly.