Upgrade switch fabrics in cr2-codfw
Closed, ResolvedPublic

Description

We didn't have the newer switch fabrics for cr2-codfw before, but we do now. We should upgrade the existing fabric with the new cards.

It seems possible to upgrade the switch fabrics one by one, but by default it wouldn't work as it would report a mismatch and offline the RE. I recall there being a command to temp disable that, best check the upgrade notes.

Details

Reference
rt8969

Event Timeline

rtimport raised the priority of this task from to Medium.Dec 18 2014, 2:19 AM
rtimport added a project: netops.
rtimport set Reference to rt8969.
mark changed the visibility from "WMF-NDA (Project)" to "Public (No Login Required)".Dec 18 2014, 3:06 PM
mark changed the edit policy from "WMF-NDA (Project)" to "All Users".
mark set Security to None.

This is now done.

We followed the process outlined by Juniper, Upgrading an MX480 SCB.

Unfortunately, this initially resulted into "FPC misconfigured" errors. It took us quite a bit to realize that we also needed to set chassis network-services enhanced-ip and reboot the REs for the new SCBs to work.

faidon claimed this task.
faidon updated the task description. (Show Details)
faidon added a project: ops-codfw.