On wtp1043, we have an alert related to a SMART failure, but upon inspection, the SMART checks pass if we `-T permissive` option:
```
wtp1043:~# smartctl -H /dev/sda
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-6-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
Short INQUIRY response, skip product id
A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.
```
```
wtp1043:~# smartctl -T permissive -H /dev/sda
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-6-amd64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
Short INQUIRY response, skip product id
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
```
... but now I see errors in the kernel logs trying to write to sda. The disk needs to be swapped out with the server powered off. No reimaging is needed, just poweroff, swap out disk, poweron