There is a disk with SMART alert on db1063 (m1 master)
It looks like disk #3
```
Enclosure Device ID: 32
Slot Number: 3
Drive's position: DiskGroup: 0, Span: 1, Arm: 1
Enclosure position: 1
Device Id: 3
WWN: 5000C50071221FC8
Sequence Number: 2
Media Error Count: 43
Other Error Count: 0
Predictive Failure Count: 1
Last Predictive Failure Event Seq Number: 2260
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: ES66
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50071221fc9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST3600057SS ES666SL7TCLQ
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :36C (96.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : Yes
```
@Cmjohnson can we get it replaced? Please ping us before replacing it so we can set it to OFFLINE manually, just to be sure.