db1059 has been complaining thru the night about the RAID policy
```
02:17 < icinga-wm> PROBLEM - MegaRAID on db1059 is CRITICAL: CRITICAL: 1 LD(s) must have write cache policy WriteBack, currently using: WriteThrough
02:37 < icinga-wm> RECOVERY - MegaRAID on db1059 is OK: OK: optimal, 1 logical, 2 physical, WriteBack policy
03:17 < icinga-wm> RECOVERY - MegaRAID on db1059 is OK: OK: optimal, 1 logical, 2 physical, WriteBack policy
05:17 < icinga-wm> PROBLEM - MegaRAID on db1059 is CRITICAL: CRITICAL: 1 LD(s) must have write cache policy WriteBack, currently using: WriteThrough
05:47 < icinga-wm> RECOVERY - MegaRAID on db1059 is OK: OK: optimal, 1 logical, 2 physical, WriteBack policy
06:17 < icinga-wm> PROBLEM - MegaRAID on db1059 is CRITICAL: CRITICAL: 1 LD(s) must have write cache policy WriteBack, currently using: WriteThrough
```
```
root@db1059:~# megacli -AdpBbuCmd -aAll
BBU status for Adapter: 0
BatteryType: BBU
Battery State: Unknown
Battery backup charge time : 0 hours
BBU Capacity Info for Adapter: 0
Relative State of Charge: 18 %
Absolute State of charge: 0 %
Remaining Capacity: 89 mAh
Full Charge Capacity: 519 mAh
Run time to empty: Battery is not being charged.
Average time to empty: 7 Min.
Estimated Time to full recharge: Battery is not being charged.
Cycle Count: 2
Max Error = 0 %
Remaining Capacity Alarm = 0 mAh
Remining Time Alarm = 0 Min
BBU Design Info for Adapter: 0
Date of Manufacture: 07/18, 2011
Design Capacity: 90 mAh
Design Voltage: 0 mV
Specification Info: 0
Serial Number: 0
Pack Stat Configuration: 0x0000
Manufacture Name:
Firmware Version : 0148 03
Device Name:
Device Chemistry:
Battery FRU: N/A
Module Version = 0148 03
Transparent Learn = 1
App Data = 1
BBU Properties for Adapter: 0
Auto Learn Period: 90 Days
Next Learn time: None Learn Delay Interval:0 Hours
Auto-Learn Mode: Disabled
```
@Cmjohnson this host is out of warranty, but do we have spare BBUs from decommissioned hosts that we can use here?