I detected this when rebooting the server:
```
Enumerating Boot options...
Enumerating Boot options... Done
UEFI0067: A PCIe link training failure is observed in Slot1 and the link is
disabled.
Do one of the following: 1) Turn off the input power to the system and turn on
again. 2) Update the PCIe device firmware. If the issue persists, contact your
service provider.
Available Actions:
F1 to Continue and Retry Boot Order
F2 for System Setup (BIOS)
F10 for Lifecycle Controller
- Enable/Configure iDRAC
- Update or Backup/Restore Server Firmware
- Help Install an Operating System
F11 for Boot Manager
```
The server wont boot.
=== DC Ops troubleshooting ==
I've not seen this, but unless it happens twice it doesn't count! So, steps to fix:
[[ https://netbox.wikimedia.org/dcim/devices/2746/ | cloudvirt1038 ]] is located in D5:U14
[x] onsite unplugs all power, fully depowering the system. Then plug back in after 15-30 seconds and attempt to boot the system. - did not fix error
[x] update firmware: idrac, bios, network card (only item on pcie bus) - did not fix error
[] - open task with dell support, have them dispatch a tech (see note below)
tech note: This error will require some troubleshooting with the network card, the PCIe riser, and the mainboard. This can be done by our own on-sites, or we can leverage our warranty coverage to have Dell send out a technician. Trying to do this via self dispatch will be cumbersome, as its unclear where to start. The options are to have an on-site self dispatch parts and work with Dell support via email to determine what parts and how to fix, or to have an on-site call into dell support and schedule a dell technician to come out and work on this in warranty host to determine what part is wrong.
**When the system is booting successfully again, please change the 'failed' state in netbox back to 'active'.**