There is a disk with SMART alert on db1065 (m2 master)
It looks like disk #1
```
Enclosure Device ID: 32
Slot Number: 1
Drive's position: DiskGroup: 0, Span: 0, Arm: 1
Enclosure position: 1
Device Id: 1
WWN: 5000C5004797CDB8
Sequence Number: 12
Media Error Count: 7588
Other Error Count: 0
Predictive Failure Count: 2
Last Predictive Failure Event Seq Number: 62914
PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors]
Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors]
Coerced Size: 558.375 GB [0x45cc0000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Device Firmware Level: ES64
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c5004797cdb9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: SEAGATE ST3600057SS ES646SL2Y79Y
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive Temperature :45C (113.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: Unknown
Drive has flagged a S.M.A.R.T alert : Yes
```
@Cmjohnson can we get it replaced? Please ping us before replacing it so we can set it to OFFLINE manually, just to be sure.