== updated checklist for request ==
cloudvirt1009 migration to 10G:
[] - put system offline in all checks for maint window
[] - relocate to 10G rack and update netbox
[] - enable PXE for 10G interfaces.
[] - update switch configuration for new primary 10G and secondary 10G ports (remove old switch port information)
[] - PXE boot and reimage system
[] - reintroduce system into service cluster
== original request ==
The server `cloudvirt1009.eqiad.wmnet` has been reallocated from a previous cluster (and renamed from `labvirt1009.eqiad.wmnet` (see parent task).
Before we put any workload, we would like to evaluate if it's possible to get 10G for this server.
However, this is what ethtool reports:
```
aborrero@cloudvirt1009:~ $ sudo ethtool ens3f0
Settings for ens3f0:
Supported ports: [ TP ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Half 1000baseT/Full
[...]
Speed: 1000Mb/s
Duplex: Full
Port: Twisted Pair
[...]
Link detected: yes
```
```
aborrero@cloudvirt1009:~ $ sudo ethtool ens3f1
Settings for ens3f1:
Supported ports: [ TP ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Half 1000baseT/Full
[...]
Speed: 1000Mb/s
Duplex: Full
Port: Twisted Pair
[...]
Link detected: yes
```
Any advice from DC-ops, @robh ?