smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-10-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: SSDSC2KB019T7R
Serial Number: BTYS810309EP1P9DGN
LU WWN Device Id: 5 5cd2e4 14f48284e
Add. Product Id: DELL(tm)
Firmware Version: SCV1DL5C
User Capacity: 1,920,383,410,176 bytes [1.92 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Feb 19 08:57:02 2021 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 288) seconds.
Offline data collection
capabilities: (0x79) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 60) minutes.
Conveyance self-test routine
recommended polling time: ( 60) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000e 130 130 039 Old_age Always - 4294967295
5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 21479
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 80
13 Read_Soft_Error_Rate 0x001e 079 079 000 Old_age Always - 281474976710655
170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0
174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 76
179 Used_Rsvd_Blk_Cnt_Tot 0x0033 100 100 010 Pre-fail Always - 0
180 Unused_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 21010
181 Program_Fail_Cnt_Total 0x003a 100 100 000 Old_age Always - 0
182 Erase_Fail_Count_Total 0x003a 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 25
195 Hardware_ECC_Recovered 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 10533
201 Unknown_SSD_Attribute 0x0033 100 100 010 Pre-fail Always - 863369628283
202 Unknown_SSD_Attribute 0x0027 100 100 000 Pre-fail Always - 0
225 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 1238904
226 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 880
227 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 61
228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 1246853
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0
233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 1238904
234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 1238904
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 2062413
245 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 100
SMART Error Log not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 1 -
# 2 Short offline Aborted by host 00% 1 -
# 3 Short offline Completed without error 00% 1 -
# 4 Vendor (0x40) Aborted by host 00% 1 -
Read SMART Selective Self-test Log failed: megasas_cmd result: 0.0 = 0/45
File Metadata
Details
Attached
Mime Type
text/plain; charset=utf-8
Storage Engine
blob
Storage Format
Raw Data
Storage Handle
8895961
Default Alt Text
Masterwork From Distant Lands (5 KB)
Attached To
Mode
P14417 Masterwork From Distant Lands
Attached
Detach File
Event Timeline
Log In to Comment