TASK AUTO-GENERATED by Nagios/Icinga RAID event handler
A degraded RAID (hpssacli) was detected on host db1092. An automatic snapshot of the current RAID status is attached below.
Please sync with the service owner to find the appropriate time window before actually replacing any failed hardware.
CRITICAL: Slot 1: Failed: 1I:1:8 - OK: 1I:1:1, 1I:1:2, 1I:1:3, 1I:1:4, 1I:1:5, 1I:1:6, 1I:1:7, 2I:2:1, 2I:2:2 - Controller: OK - Battery/Capacitor: OK $ sudo /usr/local/lib/nagios/plugins/get_raid_status_hpssacli Smart Array P840 in Slot 1 array A Logical Drive: 1 Size: 3.6 TB Fault Tolerance: 1+0 Strip Size: 256 KB Full Stripe Size: 1280 KB Status: Interim Recovery Mode MultiDomain Status: OK Caching: Disabled Disk Name: /dev/sda Mount Points: / 37.3 GB Partition Number 2 OS Status: LOCKED Mirror Group 1: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, Solid State SATA, 800 GB, OK) Mirror Group 2: physicaldrive 1I:1:6 (port 1I:box 1:bay 6, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, Solid State SATA, 800 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, Solid State SATA, 800 GB, Failed) physicaldrive 2I:2:1 (port 2I:box 2:bay 1, Solid State SATA, 800 GB, OK) physicaldrive 2I:2:2 (port 2I:box 2:bay 2, Solid State SATA, 800 GB, OK) Drive Type: Data LD Acceleration Method: HPE SSD Smart Path