The following is happening between 5 and 10 times per hour on asw1-eqsin:
%-: Member 0, interface vcp-255/0/24.32768 went down %-VCCPD_PROTOCOL_ADJDOWN: Lost adjacency to 5800.bb29.bb60 on vcp-255/0/25.32768, %-CHASSISD_VCHASSIS_MEMBER_UPDATE_NOTICE: Membership update: Member 1->1, Mode Master->Master, 1M 0B, Master Unchanged, Members Unchanged %-: self ID 0 self mode 0 master ch 0 master de 0 back ch 0 back de 0 memb ch 0 %-CHASSISD_VCHASSIS_MEMBER_UPDATE_NOTICE: Membership update: Member 1->1, Mode Master->Master, 1M 0B, Master Unchanged, Members Unchanged %-: self ID 0 self mode 0 master ch 0 master de 0 back ch 0 back de 0 memb ch 0 %-: Member 0, interface vcp-255/0/24.32768 came up
Link flapping is between member0 (rack 603) port 24 and member1 (rack 605) port 25.
Probably needs one of the following (ordered by complexity):
1/ re-seat
2/ replace cable
3/ use different ports
Depending on the timeline of T187157 we could have remote-hands investigate the issue as well.
And probably worth skipping 1/ to optimize remote-hands time, especially as we're not going to know instantly if the issue is solved.